| MEDICAL INDUSTRY |
Identification & traceability of individual biofluid storage containers
|
|
Customer need
- Read a Bar code label already glued on the partEject duplicate parts automatically
- Mark a unique identifier on each of the 48 wells in the container: 10 alphanumeric characters (OCR readable) + DataMatrix™
- Reread markings in order to validate the cycle. Record identifiers in a traceability data base
Requirements
- Total cycle time: 1 minute
- Zero Risk of non-conform parts: 100% mark verification rate
- Small marking surface: well Ø = 8.5 mm
- Customized work station installed in clean room environment
Technifor's solution
- Marking: Technifor TL400 Laser marking machine
- Vision: Cognex Insight 1010 camera + Red LED ring light
- Software: Technifor T700W linked to control PLC
|
|
|